Thermo Scientific Orion™ VERSA STAR Pro™ multi-parameter benchtop meter for

No.
LD-5362
Copy SKU
Note: Illustrations may differ or contain accessories.
More from

Delivery time

2-3 weeks

VE

1 Stück

€4,430.00
plus VAT & Shipping
Did you know? All immediately available items ordered by 10:30 a.m. leave the warehouse on the same day.
Orion™ VERSA STAR Pro™ Multi-Parameter Benchtop Meter for pH/ISE/Conductivity/Dissolved Oxygen The Thermo Scientific Orion Versa Star Pro meter with pH/ISE/Conductivity and RDO/DO modules for simultaneous measurement on up to 4 channels delivers best-in-class performance and flexibility Power supply: universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) Accuracy (barometer): plusmn;6 mmHg Accuracy (conductivity): 0.5% of reading plusmn;1 digit gt; 3 mu;S; 0.5% of reading plusmn;0.01 mu;S ≤ 3 mu;S Accuracy (ISE): plusmn;0.2 mV or plusmn;0.05% of reading whichever is greater Accuracy (DO, polarographic): plusmn;0.2 mg/L or plusmn;2% of reading whichever is greater Accuracy (RDO): plusmn;0.1 mg/L up to 8 mg/L, plusmn;0.2 mg/L from 8 to 20 mg/L, plusmn;10% of reading up to 50 mg/L Accuracy (electrical resistance): 0.5% of reading plusmn;1 digit accuracy (salinity): 0.5% of reading plusmn;1 digit accuracy (TDS): 0.5% of reading plusmn;1 digit accuracy (mV): plusmn;0.2 mV or plusmn;0.05% of reading whichever is greater accuracy (pH): ±0.002 Advanced ISE functions: Timed end point, linear point to point slope, non-linear selectable auto blank, low concentration range stability Alarm output: set point alarm, high/low limit alarm, calibration due alarm Backlight option: yes Air pressure correction:: 400 to 850mmHg, automatic using built-in barometer or manual entry Calibration: pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative Calibration modes: water saturated air, air saturated water, manual (Winkler titration), zero point Calibration points: 1 point relative mV (RmV) mode, 1 point ORP mode Calibration points (conductivity): Up to 6 Calibration points (ISE): 1 to 6 Calibration points (pH): 1 to 6 Cell constant: 0.001 to 199.9cm-1 Certification/Compliance: CE, TUV 3-1, FCC Class A Data management details: transfer single data points, multiple data points in a specified range, or all data points to a printer or computer Data points: 2000 with date and time stamp Description: Orion Versa Star Pro Benchtop Meter with VSTAR-ISE pH/mV/ISE/Temperature Module; VSTAR-CND Conductivity/TDS/Resistivity/Salinity/Temperature Module; VSTAR-RD RDO/DO/Temperature Module Kit Dimensions (L x W x H): 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add le; 2cm (0.8 in.) L H Includes: Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413µS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate inputs: BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs Isopotential point: 7.000pH (adjustable), 1.000 ISE (adjustable) Keypad: Numeric with menu-specific function keys and dual purpose scroll/shortcut keys Languages: English, Spanish, French, Italian, German, Chinese, Portuguese and Korean Type of logging function: automatic data logging in auto-read, timed and frame-by-frame modes, and manual data logging with Main memory: Non-volatile memory preserves data log, calibration log and meter settings Procedure: 10 per channel with password protection Percent Saturation Range (Polarographic DO): 0.0 to 600.0% saturation Percent Saturation Relative Accuracy (RDO): ±2 % saturation ≤ 200 % saturation, ±10 % saturation 200 % saturation Percent Saturation Resolution (Polarographic DO): 0.1, 1% saturation Saturation Range (RDO) in %: 0.0 to 500.0% saturation Percent Saturation Relative Accuracy (DO, Polarographic): ±2% saturation or ±2% of reading whichever is greater Resolution of saturation in % (RDO): 0.1, 1% saturation Supply voltage: DC input: 9VDC, 1A Power supply: Universal AC adapter (included) Pressure range: 400 to 850mmHg Pressure resolution: 0.1mmHg Range (ISE): 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none Range (ORP): plusmn;2000.0 mV Range (DO, polarographic): 0.00 to 90.00mg/L Range (RDO): 0.00 to 50.00mg/L Range (relative mV): plusmn;2000.0 mV Range relative humidity: 5 to 85%, non-condensing Resolution (conductivity): 0.001 μS minimum, auto ranging up to 4 significant digits Resolution (DO, polarographic): 0.01, 0.1mg/L Resolution (RDO): 0.01, 0.1mg/L Resolution (electrical resistance): 1 ohm or 0.1 meg-ohm, auto ranging Resolution (salinity): 0.01 psu or 0.01 ppt minimum, auto ranging Resolution (TDS): 0.001 ppm minimum, auto ranging up to 4 significant digits Resolution (mV): 0.1mV Salinity factor: 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity Measuring modes for salinity: Practical salinity (psu) or natural sea water (ppt) Stability: Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting TDS factor range: Linear (0.02 to 9.99) Temperature accuracy: plusmn;0.1deg;C Temperature compensation: Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off Operating temperature (Anglo-American): 41deg;F to 113deg;F (ambient) Operating temperature (metric): 5deg;C to 45deg;C (ambient) Reference temperature (metric): 5deg;, 10deg;, 15deg;, 20deg;, 25deg;C Temperature probe calibration: 1 point temperature offset calibration Temperature range (anglo): 22.0deg;F to 221.0deg; F Temperature resolution: 0.1deg;C, 0.1deg;F Temperature selection: Manual or automatic with ATC temperature probe Warranty: 3 year meter and module warranty Weight (anglo): 2.5 lb., modules add 0.5 lb. each Weight (metric): 1.2 kg, modules add 0.2 kg each Channels: 4 modules for customization IP rating: IP 54 Measurement Modes: pH, mV, rel. mV (RmV), ORP or ion concentration (ISE) with temperature; conductivity, TDS, salinity Outputs: USB (2), RS 232 Percent Saturation Range Polarographic DO: 0.0 to 600.0% Saturation Range (conductivity): 0.001 mu;S/cm to 3000 mS/cm Range (electrical resistance): 2 ohms to 100.0 megohms Range (salinity): 0.06 to 80.00 psu, 0.05 to 42.00 ppt Range (TDS): 0.001 to 200.0 ppm Range (mV): plusmn;2000.0 mV Range (pH): -2.000 to 20.000 Resolution (ISE): Min. 0.0001, 1 to 4 significant digits (user selectable) Resolution (pH): 0.1/0.01/0.001 Temperature Range (metric): -5.0 °C° to +105.0 °C° Unit Size: Each
How do you rate the quality of this product data?
Have we overlooked something? Has a transposed number crept in?
Your feedback helps us to improve, which benefits all our customers. Thank you!
No. LD-5362
Manufacturer (Brand) Thermo Scientific
sterile No